ALGcom Managed AC PDU-SNMP

MSRP
$369.00  
USD

SKU

37030030003

Weight

4.9 lb

Stock Quantity

Call for availability

The Managed AC PDU serves as an alternating current power distributor. It offers eight outputs, each with a capacity of up to 10A and a total device limit of 20A. When connected to the electrical grid, it operates within a range of 85 to 270 VAC.

PDUs feature robust outputs with protection against short circuits and overloads. Additionally, the Managed PDUs include alarms and indicator LEDs for each output, creating a continuous monitoring system. This ensures proactive measures are taken before potential issues become critical, keeping your infrastructure protected and in continuous operation.

Remote management and monitoring play a crucial role in these products. The models include a secure and user-friendly interface through a web browser, providing remote power monitoring, displaying information on voltage, current, and power for each output, alarms, and control of operations through an Ethernet connection, along with SNMP support for integration into your network management system.

Each output can be remotely turned on and off, allowing real-time adjustments to power distribution as needed. Scheduling activations by time and day of the week is also possible. Customizing output settings is an additional benefit; for instance, it is possible to program an Undervoltage shutdown, gradually turning off less critical outputs and directing power only where necessary.

Product Features: 

  • Input Voltage of 85- 270 VAC.
  • Total Capacity of 20 A that can be divided into eight outputs.
  • Each Output Supports up to 10 A.
  • Ethernet for Remote Monitoring via SNMP-V2 and Control through Web Page.
  • Compatible with Monitoring Systems such as Zabbix, Grafana, LibreNMS, and The Dude, among others.
  • Voltage, Current, and Power Measurement Systemper Output.
  • Remote Activation of Outputs.
  • Alert Monitoring via Web Page (Overcurrent, Overvoltage, and Undervoltage).
  • Up to 10 scheduled activations per Time and Day of the Week; Watchdog for Automatically Restarting up to 10 Devices.
  • Undervoltage Shutdown Programming, Gradually Turning off Less Critical Outputs.
  • Indicator LEDs for Individual Operation per Output.
  • Local Manual Control for Turning Outputs On/Off.
  • Robust Terminal Input Connectors are on the front panel.

Product Applications: 

  • CriticalPower Loads.
  • Telecommunication Networks.
  • Data Centers.
  • Renewable Energy Systems.
  • Alarm Systems.
INPUT 
Input Voltage (Range)85 – 270 VAC
Frequency50/60 Hz
Input CurrentUp to 20 A
ConnectionTerminal block for wires up to 4 mm2 , compatible with tubular terminal.
Input Protections20 A input circuit breaker for short-circuit and overload protection.
OUTPUT 
Output Voltage (Range)85 – 270 VAC
Current per OutputUp to 10 A
Total Outputs8
ConnectionStandard 10A NBR14136 Outlet Standard NEMA 5-15R Outlet
Output Protections20 A Input Circuit Breaker.
 Disconnects the PDU for Overcurrent, Overvoltage, and Undervoltage (User-defined on the Web Page).
MANAGEMENT INTERFACE 
Ethernet10/100 Mbps
Supported ProtocolsTCP/IP – SNMP V2
Firmware UpdatesRemote update capability for the management interface.
AlarmsAlarms for overcurrent, overvoltage, and undervoltage on input power, overcurrent per output, and output fault. (Values can be user-defined through the Web Page)
MonitoringMeasurement of voltage, current, and power individually for each output, as well as the activation status.
 Ability to customize the name of each output, facilitating the identification of connected devices
CommandsAbility to send remote commands to turn on/off and restart outputs, individually and in groups.
SchedulingPossibility to configure up to 10 schedule activations for outputs, to be defined by time and day of the week.
WatchdogPossibility to configure up to 10 watchdogs to monitor equipment availability. If the configured watchdog criteria are met, the respective output will be restarted, and the counter incremented.
Automatic Load ShutdownEach output is user-defined, with the option of manual or automatic restart.
Manual Output On/OffCommands can be executed through a button located on the front panel. Pressing it allows turning on/off all outputs.
Manual Factory ResetCommands can be executed through a button located on the front panel. Pressing it allows restoring network settings and operational configurations to factory values.
General SpecificationsManaged AC PDU
Input to Ground Isolation1000 VAC
Output to Ground Isolation1000 VAC
Operating Temperature-10 °C to 60 °C
Operating Humidity20 to 90% (non-condensing)
Alarm (Green LED)Activated and Energized Outputs
Alarm (Blinking Green LED)Failure in the Corresponding Output
MTBF>120.000 hours
Installation Mode1U Height for 19" Rack Mounts
Dimensions (H x W x D) / Weight43 x 440 x 150 mm / 2,2 kg 
1.69 X 17.32 X 5.90 inch / 4.85 lbs.